A new software version is available for your Silent Bricks System.
S3 volumes without object locking are no longer supported since version 2.57 and must be migrated. New S3 volumes include support for object locking, as well as improvements in performance and storage space requirements.
If your system is still running version 2.55 or lower, be sure to read the notes on S3.
Update.
Follow these steps to update your system:
- Make sure that your system is at least on version 2.45 or later. If in doubt, contact technical support (see end of document).
- Download the new version and save the .tar file (do not unpack the file!).
- Stop all access to the system:
a. "Eject" tapes in virtual tape libraries via the managing software.
b. Unmount SNAS volumes in the web interface and take Silent Bricks offline
c. Set all Compliant Archives offline - Important: Reboot your controller(s) before starting the update process.
- Now install the update (fast-sb-update) via the service area from the user interface and let the process complete. The system will reboot after completion.
DO NOT REBOOT THE SYSTEM BY YOURSELF! - Log in again and check the version.
Information
For all Silent Brick Controller X, Controller G and Drives.
We are currently experiencing issues with the latest software build. A new download will be available soon.
The latest valid software can be found here: https://fastlta.com/sb-sw-en
Documentation
Functionality
- Support for the new Silent Brick Max Air with Air Gap DEVSB-366
- Support for NFC tags from Silent Brick Pro DEVSB-193
- Support for quotas on SNAS volumes DEVSB-51
- Support for MS oAuth 2 when sending email notifications DEVSB-146
- Support for volume-based ejection on Silent Brick & Silent Brick Pro via API DEVSB-41
- Improvements to IPMI password policies DEVSB-45
- Optimisation of floating IP behaviour DEVSB-40
Service improvements
- Error message texts optimised DEVSB-220
- Temperature limit for warnings raised to 39°C DEVSB-213